config: change default control loop interval
On an unloaded rotator, this fixes the rapid relay toggling without needing to implement debouncing. An additional configuration validation should probably be added: the rotator rotates in azimuth about 6 deg per second. If the control loop speed is too slow or the controller angle tolerance is small enough, then the controller will never be able settle (imagine that the loop interval is 1 second. That means the rotator will move approximately 6 degrees every loop iteration, so it will always overshoot.
This commit is contained in:
parent
ccb507d4d9
commit
e4393c2e5a
@ -114,7 +114,7 @@ controller: ControllerConfig = .{
|
||||
.elevation_input = .{ .channel = .diff_23, .range = .@"5 V" },
|
||||
.azimuth_outputs = .{ .increase = .{ .io = 0 }, .decrease = .{ .io = 1 } },
|
||||
.elevation_outputs = .{ .increase = .{ .io = 2 }, .decrease = .{ .io = 3 } },
|
||||
.loop_interval_ns = 50_000_000,
|
||||
.loop_interval_ns = 100_000_000,
|
||||
.parking_posture = .{ .azimuth = 180, .elevation = 90 },
|
||||
.angle_tolerance = .{ .azimuth = 1, .elevation = 1 },
|
||||
.angle_offset = .{ .azimuth = 0, .elevation = 0 },
|
||||
|